Free Shipping on Hundreds of Products. Give us a call at 888-589-1833 and get tailored guidance from our Wine Cellar Experts.

5% OFF on All our VintageView Products with Discount Code: VINTAGEVIEW5

CellarPro  |  SKU: 37393

CellarPro Air Handler Split 4000 Horizontal #37393

$6,695.00
Shipping calculated at checkout.

Wine Storage Experts Standing By

Dial 888-589-1833 for bespoke pricing, volume discounts, and personalized cellar support.

CellarPro® · Ducted Air Handler Systems

CellarPro Air Handler Split 4000 Horizontal

Split ducted cooling system for wine cellars up to 1,000 cubic feet

1/2 Ton Split System 8" Ducted ETL Certified
Variable-Speed EC Fans
Electrofin-Coated Coils
Programmable LED Thermostat
ETL Certified to UL Standards
1/2 Ton
Nominal Capacity
3,938
BTUH High Speed
100 ft
Max Equiv. Duct Run
1,000 ft³
Cellar Capacity
Overview

As an authorized CellarPro dealer, Wine Cellar HQ offers the CellarPro Air Handler Split 4000 Horizontal, a split ducted cooling system engineered to provide maximum cooling power and adjustable humidity control for wine cellars up to 1,000 cubic feet. As a split system, the condensing unit is installed away from the evaporator to move noise and heat out of interior living spaces, and it can be ducted to indoor or outdoor environments across extreme temperature conditions ranging from -20°F to 110°F. The evaporator remains located inside the cellar and cannot be ducted from a remote location. This unit includes energy-efficient independent variable-speed EC fans with a low setting for quieter operation and a high setting for maximum power.

Key Features
Energy-efficient EC fans save $99.44 in annual energy costs versus comparable AC fans
Designed to separate the heat and noise of the condensing unit from interior living spaces
Condensing unit can be ducted to indoor or outdoor environments across extreme temperature conditions ranging from -20°F to 110°F
Cold and hot blowers are high-output centrifugal fans with variable speed control
Adjustable humidity control combines a high-output compressor with flexible fan cycles
Extra-large coils generate maximum cooling power inside the cellar
Excess condensate managed through a 1/2 inch drain line
Commercial-grade Electrofin coating protects the evaporator coils
Intuitive LED display panel mounted on the evaporator with a digital programmable thermostat
Energy-saver mode, quick-chill mode, and auto-defrost cycle
Operates with minimal vibration and less noise than comparable units
Audible and visual alarms with maintenance-needed indicator
Adjustable mounting brackets included as standard equipment
Factory-installed Expansion Valve and Liquid Line Solenoid Valve
Removable steel case and refrigerant access valve for straightforward servicing
Sight Glass and Liquid Line Filter/Drier included
Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet
Auto-reset high-pressure switch protects the system
Evaporator and condensing unit are factory-pressurized and shipped with dry nitrogen
ETL Tested and Certified to rigorous UL Standards for safety
Technical Specifications
Specification Detail
System type Split — condensing unit and evaporator sold together as one complete system
Nominal capacity 1/2 Ton
Cellar capacity Up to 1,000 cubic feet*
Cooling capacity (Sensible BTUH @ 55°F) 3,282 BTUH low / 3,617 BTUH medium / 3,938 BTUH high fan speed
Condensing unit dimensions 18.5"W x 18.5"D x 19.25"H, 111 lbs
Evaporator dimensions 30.38"W x 14.25"D x 13.25"H, 65 lbs
Shipping weight 214 lbs
Ducting Condensing unit can be ducted up to 100 equivalent feet (50 equivalent feet per duct) with 8-inch ducting, up to 30 vertical feet; evaporator is fixed inside the cellar and cannot be ducted
Electrical 115V AC / 60Hz, common dedicated 15-amp circuit; 42.0 amps startup / 9.0 amps operating (high fan speed)
Noise level, evaporator (low/med/high) 51 / 55 / 63 dbA
Noise level, condensing unit (ducted / non-ducted) 43 / 56 dBA low, 50 / 63 dBA medium, 55 / 68 dBA high
Installation & Environmental Requirements
The evaporator must be located inside the cellar and cannot be ducted from a remote location
The condensing unit must be located outside the cellar and can be ducted indoors or outdoors if needed
Fresh air intake cannot come from the wine cellar space, it must come from space outside the cellar
The evaporator should never be exposed to temperatures below 32°F, and access to its left and right sides is required for installation
Split systems must be installed and charged on site by a qualified HVAC professional
Cellar capacity above is calculated assuming R19 insulation throughout the cellar, 55°F inside the cellar, and 85°F outside the cellar; cold-side ducting, glass and/or uninsulated walls, extreme humidity, altitude, and other factors can affect actual sizing — ask your Wine Cellar HQ representative if your cellar falls outside these conditions
Downloads & Resources
Optional Upgrades

This unit can be configured with a remote wired LED display kit, an outdoor hood for the condensing unit, a networkable Ecobee thermostat upgrade, a bottle probe, and a line set for installations requiring additional length. Ask your Wine Cellar HQ representative for current options and pricing.

Backed by CellarPro's 2-year full system warranty and 5-year compressor warranty. To activate the warranty, a completed Split Installation Checklist must be returned. An extended warranty option is also available.

Ships strapped to a pallet via common carrier with curbside delivery. Typical processing time is 5-10 business days.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.